Warning: include(/home/quintpub/public_html/journals/prd/includes/code.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 2

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prd/includes/code.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 2
Performance of Immediately Loaded Short Implants Using Low-Speed Drilling Protocol and Plasma Rich in Growth Factors: A Controlled Retrospective Observational Study
Warning: include(/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 39

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 39
Follow Us      

LOGIN

   Official Journal of The Academy of Osseointegration

 
Share Page:
Back

Volume 43 , Issue 2
March/April 2023

Pages 232–239b


Performance of Immediately Loaded Short Implants Using Low-Speed Drilling Protocol and Plasma Rich in Growth Factors: A Controlled Retrospective Observational Study

Eduardo Anitua, DDS, MD, PhD/Carlos Flores, DDS/Sofía Fernández-de-Retana, PhD/Beatriz Anitua, BDS/Mohammad H. Alkhraisat, DDS, PhD, EuPhD


DOI: 10.11607/prd.5203

Short dental implants are an alternative to surgical bone augmentation procedures and the placement of longer implants. The high predictability of short implants has encouraged clinicians to load them immediately. However, there are few studies assessing the influence of immediate vs delayed loading of short (< 8 mm) implants. The purpose of this retrospective study was to report the mid-term (5-year) outcomes (survival and marginal bone loss [MBL]) of immediate vs delayed loading of short implants. A total of 44 patients with 149 short implants fulfilled the inclusion criteria (95 and 54 implants with delayed and immediate loading, respectively). During the follow-up period, descriptive clinical variables, implant survival, MBL, and prosthetic complications were recorded and statistically analyzed. The mean follow-up time was 60 ± 40 months. The overall cumulative implant survival was 95.6%, and MBL was –0.1 ± 0.7 mm. No statistically significant differences were detected between the immediate and delayed loading groups in terms of implant survival (92.6% vs 97.5%) or MBL (–0.2 ± 0.8 mm vs –0.1 ± 0.7 mm), respectively. According to the results of this study, the immediate loading of short implants demonstrated predictability at the mid-term follow-up time. These results must be confirmed in future prospective studies.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2020 Quintessence Publishing Co, Inc

PRD Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help